Polydata

Wireless data collector – Polydata

Temperature, pressure, flow, speed, cycles · WiFi + USB · RS232, HTTP, WebSocket, MQTT · 2 opto-isolated inputs · 2 relay outputs · Thresholds with email alerts

Polydata wireless data collector — black enclosure with display, front view

Every process value, collected and stored

Polydata is a universal module that collects your process data from one minute and stores it in the Polymorf database.

Universal collection

One module for all your process values.

  • Temperature, pressure, flow, speed, cycles
  • From 1 minute into the Polymorf database
  • Integrated temperature sensor
  • 2 opto-isolated inputs 3–32 V

Thresholds + email alarms

Every breach triggers an alert with action.

  • Configurable min and max thresholds
  • Alarms + email alerts
  • Predictive maintenance
  • 2 driven relay outputs

Wired + wireless

The module talks to your tools, wired or not.

  • WiFi + USB
  • RS232, HTTP, WebSocket, MQTT
  • Configuration via WiFi portal
  • Status LCD screen

Included

Included system

  • Collection from 1 minute
  • Temperature, pressure, flow, speed, cycles
  • Min/max thresholds + alarms
  • Email alerts
  • Predictive maintenance
  • WiFi + USB
  • RS232, HTTP, WebSocket, MQTT
  • Integrated temperature sensor
  • 2 opto-isolated inputs
  • 2 relay outputs
  • 5 or 24 V DC power
  • Configuration via 192.168.4.1 portal

Specifications

Polydata technical specifications

Power5 or 24 V DC
Inputs2 opto-isolated 3–32 V DC
Outputs2 relays
SensorIntegrated temperature
RateFrom 1 minute into the Polymorf database + optional real-time notification starting from 100 ms latency
CommunicationRS232, HTTP, WebSocket, MQTT
ConnectivityUSB, WiFi
Configuration192.168.4.1 WiFi portal + LCD screen
DatabasePolymorf — Manufacturing, SCADA, Maintenance, Stock

Overview

The module that feeds Polymorf

Polydata is a universal module for collecting process and production data: temperature, pressure, flow, speed, cycle count. Readings go over WiFi into the Polymorf database, from one minute.

Real Polydata unit and CAD render — OLED display showing 17.50 °C next to the enclosure render

In the field

Your compressors live in Polymorf SCADA

Here, a Polydata unit streams compressor readings: voltage, temperature, pressure, flow, humidity — every value trends, every breach alerts.

In the tree, each device keeps its readings: current, flow, humidity, pressure, temperature, voltage. The collector photo, linked to the device, proves the link between field and screen.

Polymorf SCADA fed by Polydata — live compressor readings with collector photo

FAQ

Frequently asked questions

Connect to the Polydata access point with password 123456789, open 192.168.4.1, Settings tab: device name, local WiFi and password, Polymorf host and MQTT broker — Save, then Reboot when Ready shows. Parameters display on the screen.

Configurable rate from one minute, stored in the Polymorf database. Optional real-time notification starting from 100 ms latency.

Set min and/or max thresholds: on-device alarms, email alerts, or event triggers like predictive maintenance in the Maintenance module.

Manufacturing, SCADA, Maintenance and Stock of the Polymorf suite.

5 or 24 V DC, 2 opto-isolated inputs 3–32 V, 2 relay outputs, integrated temperature sensor, USB and WiFi, RS232, HTTP, WebSocket and MQTT communication.

Hardware

Discover the other devices

Mains and temperature monitor

Timestamped outages, climate under alarm

Discover

IT32B Continuity Tester

32-point wiring test in 1 second

Discover

Process data to collect? Let’s talk.

Describe your values, rates and Polymorf modules — we reply within 24 hours with next steps.